{"id":71316,"date":"2016-03-29T11:55:20","date_gmt":"2016-03-29T15:55:20","guid":{"rendered":"http:\/\/www.eprup.com\/ng\/?page_id=71316"},"modified":"2016-03-29T11:55:20","modified_gmt":"2016-03-29T15:55:20","slug":"h2s-removal-amine","status":"publish","type":"page","link":"https:\/\/www.newpointgas.com\/project\/h2s-removal-amine\/","title":{"rendered":"H2S Removal \u2013 Amine"},"content":{"rendered":"
[vc_row type=”container” css=”.vc_custom_1459262447528{padding-top: 45px !important;padding-bottom: 15px !important;}”][vc_column][vc_column_text]<\/p>\n
[\/vc_column_text][vc_separator color=”#af8c30″ type=”normal” thickness=”1″ up=”0″ down=”25″][vc_row_inner][vc_column_inner width=”1\/4″][vc_single_image image=”71261″ img_size=”384×256″ alignment=”center” style=”vc_box_shadow_border”][vc_column_text]<\/p>\n
[\/vc_column_text][\/vc_column_inner][vc_column_inner width=”3\/4″][vc_column_text]<\/p>\n
Project Location: Freer, Texas<\/p>\n
90 GPM MDEA Amine Plant for the removal of CO2 and H2S from natural gas stream in Texas.<\/p>\n
Inlet gas stream of 12 MMscfd containing a CO2 concentration of 15% and H2S concentration of 150 PPM. Duties include: installation, startup, maintenance, and operations.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row full_width=”stretch_row” type=”container” css=”.vc_custom_1459262551511{padding-top: 45px !important;padding-bottom: 15px !important;background-color: #fafafa !important;}”][vc_column][vc_column_text]<\/p>\n
[\/vc_column_text][vc_separator color=”#af8c30″ type=”normal” thickness=”1″ up=”0″ down=”25″][vc_row_inner][vc_column_inner width=”1\/4″][vc_single_image image=”71269″ img_size=”384×256″ alignment=”center” style=”vc_box_shadow_border”][vc_column_text]<\/p>\n
[\/vc_column_text][\/vc_column_inner][vc_column_inner width=”3\/4″][vc_column_text]<\/p>\n
Project Location: Dolce, New Mexico<\/p>\n
10 GPM MDEA Amine Plant for the removal of H2S and included Acid Gas Injection for acid gas disposal in New Mexico.<\/p>\n
Inlet gas stream of 12 MMscfd containing a H2S concentration of 2,200 PPM. Expanded to accommodate 25 MMscfd. Duties include: installation, startup and maintenance.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row type=”container” css=”.vc_custom_1459262447528{padding-top: 45px !important;padding-bottom: 15px !important;}”][vc_column][vc_column_text]<\/p>\n
[\/vc_column_text][vc_separator color=”#af8c30″ type=”normal” thickness=”1″ up=”0″ down=”25″][vc_row_inner][vc_column_inner width=”1\/4″][vc_single_image image=”71246″ img_size=”366×256″ alignment=”center” style=”vc_box_shadow_border”][vc_column_text]<\/p>\n
[\/vc_column_text][\/vc_column_inner][vc_column_inner width=”3\/4″][vc_column_text]<\/p>\n
Project Location: Manderson, Wyoming<\/p>\n
270 GPM DGA Amine Plant for the H2S removal from natural gas stream in Wyoming and included Acid Gas Injection for acid gas disposal.<\/p>\n
Inlet gas stream of 12 MMscfd with a H2S concentration of 230,000 PPM reduced to pipeline spec of 4 PPM. Duties include: installation, startup, maintenance, and operations.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row full_width=”stretch_row” type=”container” css=”.vc_custom_1459262551511{padding-top: 45px !important;padding-bottom: 15px !important;background-color: #fafafa !important;}”][vc_column][vc_column_text]<\/p>\n
[\/vc_column_text][vc_separator color=”#af8c30″ type=”normal” thickness=”1″ up=”0″ down=”25″][vc_row_inner][vc_column_inner width=”1\/4″][vc_single_image image=”71261″ img_size=”384×256″ alignment=”center” style=”vc_box_shadow_border”][vc_column_text]<\/p>\n
[\/vc_column_text][\/vc_column_inner][vc_column_inner width=”3\/4″][vc_column_text]<\/p>\n
Project Location: Port Arthur, Texas<\/p>\n
60 GPM DEA Amine Plant for the removal of CO2 and H2S from natural gas stream in Texas.<\/p>\n
Inlet gas stream of 11 MMscfd with a CO2 concentration of 8% reduced to pipeline spec of 3%. Duties include: installation, startup, and maintenance.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row type=”container” css=”.vc_custom_1459262447528{padding-top: 45px !important;padding-bottom: 15px !important;}”][vc_column][vc_column_text]<\/p>\n
[\/vc_column_text][vc_separator color=”#af8c30″ type=”normal” thickness=”1″ up=”0″ down=”25″][vc_row_inner][vc_column_inner width=”1\/4″][vc_single_image image=”71261″ img_size=”384×256″ alignment=”center” style=”vc_box_shadow_border”][vc_column_text]<\/p>\n
[\/vc_column_text][\/vc_column_inner][vc_column_inner width=”3\/4″][vc_column_text]<\/p>\n
Project Location: Dimmit County, TX<\/p>\n
Removed 300 ppm H2S from varying amounts of gas during well tests at several locations.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row full_width=”stretch_row” type=”container” css=”.vc_custom_1459262551511{padding-top: 45px !important;padding-bottom: 15px !important;background-color: #fafafa !important;}”][vc_column][vc_column_text]<\/p>\n
[\/vc_column_text][vc_separator color=”#af8c30″ type=”normal” thickness=”1″ up=”0″ down=”25″][vc_row_inner][vc_column_inner width=”1\/4″][vc_single_image image=”71261″ img_size=”384×256″ alignment=”center” style=”vc_box_shadow_border”][vc_column_text]<\/p>\n
[\/vc_column_text][\/vc_column_inner][vc_column_inner width=”3\/4″][vc_column_text]<\/p>\n
Project Location: Winchester, Texas<\/p>\n
160 GPM MDEA Amine Plant for the removal of H2S and Cryogenic Gas Processing Facility.<\/p>\n
Inlet gas stream of 100 MMscfd containing an H2S concentration of 12-15 PPM. Facility included dehydration and hydrocarbon liquid recovery. Duties include: maintenance and operations.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row type=”container” css=”.vc_custom_1459262447528{padding-top: 45px !important;padding-bottom: 15px !important;}”][vc_column][vc_column_text]<\/p>\n
[\/vc_column_text][vc_separator color=”#af8c30″ type=”normal” thickness=”1″ up=”0″ down=”25″][vc_row_inner][vc_column_inner width=”1\/4″][vc_single_image image=”71269″ img_size=”384×256″ alignment=”center” style=”vc_box_shadow_border”][vc_column_text]<\/p>\n
[\/vc_column_text][\/vc_column_inner][vc_column_inner width=”3\/4″][vc_column_text]<\/p>\n
Project Location: Milensand, New Mexico<\/p>\n
500 GPM MEA Amine Plant for the removal of CO2 and H2S, a Lean Oil Adsorption Plant and a Claus Sulfur Plant.<\/p>\n
Inlet gas stream of 43 MMscfd containing CO2 and H2S. The lean oil absorption plant enabled ethane recovery, as well as gasoline, butane, and propane distillation. The Claus Sulfur Plant converted the H2S into elemental sulfur. Duties include: maintenance and operations.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row full_width=”stretch_row” type=”container” css=”.vc_custom_1459262551511{padding-top: 45px !important;padding-bottom: 15px !important;background-color: #fafafa !important;}”][vc_column][vc_column_text]<\/p>\n
[\/vc_column_text][vc_separator color=”#af8c30″ type=”normal” thickness=”1″ up=”0″ down=”25″][vc_row_inner][vc_column_inner width=”1\/4″][vc_single_image image=”71261″ img_size=”384×256″ alignment=”center” style=”vc_box_shadow_border”][vc_column_text]<\/p>\n
[\/vc_column_text][\/vc_column_inner][vc_column_inner width=”3\/4″][vc_column_text]<\/p>\n
Project Location: Longview, Texas<\/p>\n
110 GPM DEA Amine Plant for the removal of H2S and natural gas Refrigeration Processing Plant.<\/p>\n
Inlet gas stream of 12 MMscfd with a H2S concentration of 230,000 PPM reduced to pipeline spec of 4 PPM. Duties include: installation, startup, maintenance, and operations.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row type=”container” css=”.vc_custom_1459262447528{padding-top: 45px !important;padding-bottom: 15px !important;}”][vc_column][vc_column_text]<\/p>\n
[\/vc_column_text][vc_separator color=”#af8c30″ type=”normal” thickness=”1″ up=”0″ down=”25″][vc_row_inner][vc_column_inner width=”1\/4″][vc_single_image image=”71261″ img_size=”384×256″ alignment=”center” style=”vc_box_shadow_border”][vc_column_text]<\/p>\n
[\/vc_column_text][\/vc_column_inner][vc_column_inner width=”3\/4″][vc_column_text]<\/p>\n
Project Location: Yoakum, TX<\/p>\n
60 GPM MDEA Amine Plant for the removal of CO2 and H2S from natural gas in Texas.<\/p>\n
Inlet gas stream of 8 MMscfd containing a CO2 concentration of 15% and H2S concentration of 200 PPM. Expanded to accommodate 15 MMscfd, same conditions. Duties include: installation, startup, maintenance and operations.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row full_width=”stretch_row” type=”container” css=”.vc_custom_1459262551511{padding-top: 45px !important;padding-bottom: 15px !important;background-color: #fafafa !important;}”][vc_column][vc_column_text]<\/p>\n
[\/vc_column_text][vc_separator color=”#af8c30″ type=”normal” thickness=”1″ up=”0″ down=”25″][vc_row_inner][vc_column_inner width=”1\/4″][vc_single_image image=”71284″ img_size=”462×227″ alignment=”center” style=”vc_box_shadow_border”][vc_column_text]<\/p>\n
[\/vc_column_text][\/vc_column_inner][vc_column_inner width=”3\/4″][vc_column_text]<\/p>\n
Project Location: Abu Dhabi[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"
[vc_row type=”container” css=”.vc_custom_1459262447528{padding-top: 45px !important;padding-bottom: 15px !important;}”][vc_column][vc_column_text] 90 GPM Amine Plant [\/vc_column_text][vc_separator color=”#af8c30″ type=”normal” thickness=”1″ up=”0″ down=”25″][vc_row_inner][vc_column_inner width=”1\/4″][vc_single_image image=”71261″ img_size=”384×256″ alignment=”center” style=”vc_box_shadow_border”][vc_column_text] Services Included CO2 Removal \u2013 Amine H2S Removal \u2013 Amine [\/vc_column_text][\/vc_column_inner][vc_column_inner width=”3\/4″][vc_column_text] Project Details Project Location: Freer, Texas 90 GPM MDEA Amine Plant for the removal of CO2 and H2S from natural gas […]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":15,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-full-width.php","meta":{"_acf_changed":false,"footnotes":""},"acf":[],"yoast_head":"\n